{"product_id":"io-hvac-controls-ut-swm-universal-thermostat-smart-wire-module","title":"iO HVAC Controls UT-SWM Universal Thermostat Smart Wire Module","description":"\u003cp data-start=\"307\" data-end=\"697\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eUT-SWM Universal Thermostat Smart Wire Module | iO HVAC Controls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"307\" data-end=\"697\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"311\" data-end=\"368\"\u003eiO HVAC UT-SWM Universal Thermostat Smart Wire Module\u003c\/strong\u003e is an innovative \u003cstrong data-start=\"386\" data-end=\"409\"\u003e2-to-7 wire adapter\u003c\/strong\u003e designed to expand thermostat capabilities without the need to run additional wiring. Perfect for retrofit applications, the UT-SWM allows contractors to add up to \u003cstrong data-start=\"574\" data-end=\"601\"\u003efive additional outputs\u003c\/strong\u003e over a single pair of existing thermostat wires, saving both installation time and labor costs.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"699\" data-end=\"1004\"\u003eIdeal for situations where pulling new wire is difficult or impossible, the UT-SWM provides a simple and cost-effective solution for upgrading HVAC systems. Compatible with both \u003cstrong data-start=\"877\" data-end=\"920\"\u003eheat pump and conventional HVAC systems\u003c\/strong\u003e, this universal smart wire module works with virtually all major thermostat brands.\u003c\/p\u003e\n\u003cp data-start=\"1006\" data-end=\"1209\"\u003eThe compact system includes both a \u003cstrong data-start=\"1041\" data-end=\"1058\"\u003esender module\u003c\/strong\u003e and a \u003cstrong data-start=\"1065\" data-end=\"1090\"\u003erelay receiver module\u003c\/strong\u003e, making it easy to add functionality between the thermostat and indoor HVAC equipment while utilizing existing wiring.\u003c\/p\u003e\n\u003cp data-start=\"1211\" data-end=\"1427\"\u003eWhether you're replacing an outdated thermostat, upgrading equipment, or solving limited wiring issues, the \u003cstrong data-start=\"1319\" data-end=\"1368\"\u003eUT-SWM Universal Thermostat Smart Wire Module\u003c\/strong\u003e delivers reliable performance and simplified installation.\u003c\/p\u003e\n\u003chr data-start=\"1429\" data-end=\"1432\"\u003e\n\u003cp data-section-id=\"1iz91iu\" data-start=\"1434\" data-end=\"1450\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1452\" data-end=\"1905\"\u003e\n\u003cli data-section-id=\"41caeb\" data-start=\"1452\" data-end=\"1513\"\u003eConverts \u003cstrong data-start=\"1463\" data-end=\"1513\"\u003e2 existing wires into up to 7 thermostat wires\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"67j220\" data-start=\"1514\" data-end=\"1579\"\u003eAdds up to \u003cstrong data-start=\"1527\" data-end=\"1551\"\u003e5 additional outputs\u003c\/strong\u003e over a single pair of wires\u003c\/li\u003e\n\u003cli data-section-id=\"1dy2gwb\" data-start=\"1580\" data-end=\"1630\"\u003eEliminates the need to run new thermostat wiring\u003c\/li\u003e\n\u003cli data-section-id=\"hw0hub\" data-start=\"1631\" data-end=\"1674\"\u003eReduces installation time and labor costs\u003c\/li\u003e\n\u003cli data-section-id=\"16ox15e\" data-start=\"1675\" data-end=\"1741\"\u003eCompatible with both \u003cstrong data-start=\"1698\" data-end=\"1741\"\u003eheat pump and conventional HVAC systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12f0vtx\" data-start=\"1742\" data-end=\"1792\"\u003eWorks with virtually all major thermostat brands\u003c\/li\u003e\n\u003cli data-section-id=\"1pa8upm\" data-start=\"1793\" data-end=\"1859\"\u003eIncludes compact \u003cstrong data-start=\"1812\" data-end=\"1829\"\u003esender module\u003c\/strong\u003e and \u003cstrong data-start=\"1834\" data-end=\"1859\"\u003erelay receiver module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l1zzkx\" data-start=\"1860\" data-end=\"1905\"\u003eIdeal for retrofit and upgrade applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1907\" data-end=\"1910\"\u003e\n\u003cp data-section-id=\"nucr17\" data-start=\"1912\" data-end=\"1940\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1942\" data-end=\"2484\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1942\" data-end=\"1969\"\u003e\n\u003ctr data-start=\"1942\" data-end=\"1969\"\u003e\n\u003cth data-start=\"1942\" data-end=\"1958\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1958\" data-end=\"1969\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1980\" data-end=\"2484\"\u003e\n\u003ctr data-start=\"1980\" data-end=\"1998\"\u003e\n\u003ctd data-start=\"1980\" data-end=\"1988\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1988\" data-end=\"1998\"\u003eUT-SWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1999\" data-end=\"2056\"\u003e\n\u003ctd data-start=\"1999\" data-end=\"2014\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2014\" data-end=\"2056\"\u003eUniversal Thermostat Smart Wire Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2057\" data-end=\"2094\"\u003e\n\u003ctd data-start=\"2057\" data-end=\"2071\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2071\" data-end=\"2094\"\u003e2-to-7 Wire Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2095\" data-end=\"2120\"\u003e\n\u003ctd data-start=\"2095\" data-end=\"2110\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2110\" data-end=\"2120\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2121\" data-end=\"2187\"\u003e\n\u003ctd data-start=\"2121\" data-end=\"2141\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2141\" data-end=\"2187\"\u003e0.15mA (No Relays), 0.45mA (All Relays On)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2188\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2188\" data-end=\"2211\" data-col-size=\"sm\"\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2211\" data-end=\"2231\"\u003e0.5 Amp @ 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2279\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2258\" data-col-size=\"sm\"\u003eRelay Switching Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2258\" data-end=\"2279\"\u003e1 Amp per contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2280\" data-end=\"2309\"\u003e\n\u003ctd data-start=\"2280\" data-end=\"2299\" data-col-size=\"sm\"\u003eMaximum Distance\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2299\" data-end=\"2309\"\u003e250 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2310\" data-end=\"2348\"\u003e\n\u003ctd data-start=\"2310\" data-end=\"2329\" data-col-size=\"sm\"\u003eTransmission Lag\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2329\" data-end=\"2348\"\u003eUp to 5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2349\" data-end=\"2406\"\u003e\n\u003ctd data-start=\"2349\" data-end=\"2381\" data-col-size=\"sm\"\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2381\" data-end=\"2406\"\u003e122°F (150°F Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2407\" data-end=\"2462\"\u003e\n\u003ctd data-start=\"2407\" data-end=\"2435\" data-col-size=\"sm\"\u003eMaximum Relative Humidity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2435\" data-end=\"2462\"\u003e95% RH (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2463\" data-end=\"2484\"\u003e\n\u003ctd data-start=\"2463\" data-end=\"2474\" data-col-size=\"sm\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2484\" data-col-size=\"md\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cbr\u003e\n  \u003cp\u003e\u003cstrong\u003eTechnical Documents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/UT-SWM-Installation-Instructions-Rev2.1.pdf?v=1782401138\" title=\"UT-SWM Installation Manual\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/UT-SWM-Product-Brochure.pdf?v=1782401138\" title=\"UT-SWM Product Brochure\"\u003eUT-SWM Product Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"IO HVAC","offers":[{"title":"Default Title","offer_id":45664224084021,"sku":"UT-SWM","price":128.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/b4a5e5da-4ca3-4818-8fa0-5c1098db9711.png?v=1782339471","url":"https:\/\/plumbestore.com\/products\/io-hvac-controls-ut-swm-universal-thermostat-smart-wire-module","provider":"plumbEstore","version":"1.0","type":"link"}