{"product_id":"io-wr-wireless-relay-kit-hvac-wireless-control-system","title":"iO HVAC Controls iO-WRP 4 Channel Wireless Relay PLUS Kit","description":"\u003ch5 data-section-id=\"12cgd8m\" data-start=\"0\" data-end=\"73\" class=\"PDq2pG_selectionAnchorContainer\"\u003eWireless Relay Kit – 915 MHz HVAC Wireless Communication System\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cp data-section-id=\"1k8uwy3\" data-start=\"75\" data-end=\"98\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"100\" data-end=\"408\"\u003eEliminate the need for additional control wiring with the \u003cstrong data-start=\"158\" data-end=\"187\"\u003eiO-WRP Wireless Relay Kit\u003c\/strong\u003e. Designed specifically for HVAC applications, this wireless communication system provides a reliable connection between indoor and outdoor equipment when running new thermostat wire is impractical, costly, or impossible.\u003c\/p\u003e\n\u003cp data-start=\"410\" data-end=\"798\"\u003eOperating on a dependable \u003cstrong data-start=\"436\" data-end=\"457\"\u003e915 MHz frequency\u003c\/strong\u003e, the iO-WRP allows contractors to wirelessly control and monitor heat pumps, condensing units, fans, pumps, lighting systems, and other industrial equipment. With support for \u003cstrong data-start=\"633\" data-end=\"659\"\u003efour wireless channels\u003c\/strong\u003e and a communication range of up to \u003cstrong data-start=\"695\" data-end=\"707\"\u003e1\/4 mile\u003c\/strong\u003e, the system offers exceptional flexibility for retrofit and new construction applications.\u003c\/p\u003e\n\u003cp data-start=\"800\" data-end=\"1005\"\u003eFactory-paired for quick installation, multiple wireless relay pairs can be installed within the same building, making the iO-WRP an ideal solution for residential, commercial, and industrial HVAC systems.\u003c\/p\u003e\n\u003cp data-start=\"1007\" data-end=\"1185\"\u003eWhether you're upgrading a heat pump system or replacing damaged control wiring, the iO-WRP Wireless Relay Kit provides a fast, reliable, and cost-effective wireless alternative.\u003c\/p\u003e\n\u003chr data-start=\"1187\" data-end=\"1190\"\u003e\n\u003cp data-section-id=\"1iz91iu\" data-start=\"1192\" data-end=\"1208\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1210\" data-end=\"1762\"\u003e\n\u003cli data-section-id=\"zlvozd\" data-start=\"1210\" data-end=\"1262\"\u003eEliminates the need for running new control wiring\u003c\/li\u003e\n\u003cli data-section-id=\"4x7m5u\" data-start=\"1263\" data-end=\"1319\"\u003eIdeal for heat pump upgrades and retrofit applications\u003c\/li\u003e\n\u003cli data-section-id=\"oy0vm\" data-start=\"1320\" data-end=\"1365\"\u003eReliable \u003cstrong data-start=\"1331\" data-end=\"1365\"\u003e915 MHz wireless communication\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k7fmq6\" data-start=\"1366\" data-end=\"1406\"\u003eSupports up to \u003cstrong data-start=\"1383\" data-end=\"1406\"\u003e4 wireless channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16s10x4\" data-start=\"1407\" data-end=\"1531\"\u003eControls or monitors:\n\u003cul data-start=\"1433\" data-end=\"1531\"\u003e\n\u003cli data-section-id=\"jf9mxn\" data-start=\"1433\" data-end=\"1445\"\u003eHeat pumps\u003c\/li\u003e\n\u003cli data-section-id=\"1yl6voj\" data-start=\"1448\" data-end=\"1466\"\u003eCondensing units\u003c\/li\u003e\n\u003cli data-section-id=\"1j455le\" data-start=\"1469\" data-end=\"1475\"\u003eFans\u003c\/li\u003e\n\u003cli data-section-id=\"174z683\" data-start=\"1478\" data-end=\"1485\"\u003ePumps\u003c\/li\u003e\n\u003cli data-section-id=\"247tk0\" data-start=\"1488\" data-end=\"1506\"\u003eLighting systems\u003c\/li\u003e\n\u003cli data-section-id=\"16wih39\" data-start=\"1509\" data-end=\"1531\"\u003eIndustrial equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lv3n2\" data-start=\"1532\" data-end=\"1572\"\u003eCommunication range up to \u003cstrong data-start=\"1560\" data-end=\"1572\"\u003e1\/4 mile\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s74y1f\" data-start=\"1573\" data-end=\"1611\"\u003eFactory-paired for easy installation\u003c\/li\u003e\n\u003cli data-section-id=\"1tfho3o\" data-start=\"1612\" data-end=\"1676\"\u003eMultiple wireless relay pairs can operate in the same building\u003c\/li\u003e\n\u003cli data-section-id=\"lthsm\" data-start=\"1677\" data-end=\"1729\"\u003eOperates using \u003cstrong data-start=\"1694\" data-end=\"1729\"\u003e24 VAC input and signal voltage\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pfk27h\" data-start=\"1730\" data-end=\"1762\"\u003eOne-year manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1764\" data-end=\"1767\"\u003e\n\u003cp data-section-id=\"nucr17\" data-start=\"1769\" data-end=\"1797\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1799\" data-end=\"2228\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1799\" data-end=\"1826\"\u003e\n\u003ctr data-start=\"1799\" data-end=\"1826\"\u003e\n\u003cth data-start=\"1799\" data-end=\"1815\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1815\" data-end=\"1826\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1837\" data-end=\"2228\"\u003e\n\u003ctr data-start=\"1837\" data-end=\"1874\"\u003e\n\u003ctd data-start=\"1837\" data-end=\"1845\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1845\" data-end=\"1874\"\u003eiO-WRP Wireless Relay Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1875\" data-end=\"1908\"\u003e\n\u003ctd data-start=\"1875\" data-end=\"1897\" data-col-size=\"sm\"\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1897\" data-end=\"1908\"\u003e915 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1909\" data-end=\"1960\"\u003e\n\u003ctd data-start=\"1909\" data-end=\"1931\" data-col-size=\"sm\"\u003eCommunication Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1931\" data-end=\"1960\"\u003eUp to 1\/4 mile (1,320 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1961\" data-end=\"1987\"\u003e\n\u003ctd data-start=\"1961\" data-end=\"1977\" data-col-size=\"sm\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1977\" data-end=\"1987\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1988\" data-end=\"2020\"\u003e\n\u003ctd data-start=\"1988\" data-end=\"2010\" data-col-size=\"sm\"\u003eSignal Input\/Output\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2010\" data-end=\"2020\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2021\" data-end=\"2046\"\u003e\n\u003ctd data-start=\"2021\" data-end=\"2041\" data-col-size=\"sm\"\u003eWireless Channels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2041\" data-end=\"2046\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2047\" data-end=\"2082\"\u003e\n\u003ctd data-start=\"2047\" data-end=\"2064\" data-col-size=\"sm\"\u003eContact Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2064\" data-end=\"2082\"\u003e1A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2083\" data-end=\"2130\"\u003e\n\u003ctd data-start=\"2083\" data-end=\"2096\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2096\" data-end=\"2130\"\u003e5.125\" H x 2.625\" W x 1.125\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2131\" data-end=\"2206\"\u003e\n\u003ctd data-start=\"2131\" data-end=\"2147\" data-col-size=\"sm\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd data-start=\"2147\" data-end=\"2206\" data-col-size=\"md\"\u003eBase: 3 Send \/ 1 Receive; Satellite: 3 Receive \/ 1 Send\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2207\" data-end=\"2228\"\u003e\n\u003ctd data-start=\"2207\" data-end=\"2218\" data-col-size=\"sm\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-start=\"2218\" data-end=\"2228\" data-col-size=\"md\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2230\" data-end=\"2233\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Documents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"IO-WRP Product Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/iO-WRP-Product-Brochure.pdf?v=1782400984\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"IO-WRP Wiring Diagram\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/Using-Wireless-Relay-with-Dry-Contact-Input-Output-1.pdf?v=1782400984\"\u003eWiring Diagram for Dry Contacts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"IO-WRP Installation Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/iO-WRP-Installation-Manual-v1.0.2.pdf?v=1782400984\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"IO HVAC","offers":[{"title":"Default Title","offer_id":45665672757301,"sku":null,"price":439.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/94d96bd5-fd2f-4445-abc0-2c5c78eb5525.png?v=1782334783","url":"https:\/\/plumbestore.com\/products\/io-wr-wireless-relay-kit-hvac-wireless-control-system","provider":"plumbEstore","version":"1.0","type":"link"}