{"product_id":"sanco2-505-gallon-storage-tank-eco-1000glnsm","title":"SANCO2 1000 Gallon Storage Tank ECO-1000GLNSM","description":"\u003cstyle\u003e\n  .sanco-storage {\n    --sc-navy: #073b60;\n    --sc-green: #77b83e;\n    --sc-pale: #eef7fb;\n    --sc-hover: #edf6e5;\n    --sc-border: #d4e0e6;\n    width: 100%;\n    max-width: 100%;\n    min-width: 0;\n    color: #243746;\n    background: #ffffff;\n    font-size: 16px;\n    line-height: 1.65;\n    overflow-wrap: break-word;\n  }\n\n  .sanco-storage,\n  .sanco-storage * {\n    box-sizing: border-box;\n  }\n\n  .sanco-storage h2,\n  .sanco-storage h3 {\n    color: #000000 !important;\n    font-weight: 700;\n    line-height: 1.3;\n    letter-spacing: normal;\n    text-transform: none;\n  }\n\n  .sanco-storage h2 {\n    margin: 26px 0 12px;\n    font-size: clamp(20px, 2.4vw, 26px);\n  }\n\n  .sanco-storage h2:first-child {\n    margin-top: 0;\n  }\n\n  .sanco-storage h3 {\n    margin: 20px 0 10px;\n    font-size: clamp(18px, 2vw, 22px);\n  }\n\n  .sanco-storage p {\n    margin: 0 0 16px;\n  }\n\n  .sanco-storage .sc-section {\n    margin-top: 26px;\n    padding-top: 2px;\n    border-top: 3px solid var(--sc-green);\n  }\n\n  .sanco-storage .sc-table-wrap {\n    width: 100%;\n    max-width: 100%;\n    margin: 14px 0 22px;\n  }\n\n  .sanco-storage .sc-table {\n    width: 100%;\n    max-width: 100%;\n    table-layout: fixed;\n    border-collapse: collapse;\n    font-size: 14px;\n    line-height: 1.5;\n  }\n\n  .sanco-storage .sc-label {\n    width: 40%;\n  }\n\n  .sanco-storage .sc-value {\n    width: 60%;\n  }\n\n  .sanco-storage .sc-table th,\n  .sanco-storage .sc-table td {\n    padding: 8px 10px;\n    border: 1px solid var(--sc-border);\n    text-align: left;\n    vertical-align: top;\n    white-space: normal;\n    overflow-wrap: anywhere;\n    color: #243746;\n  }\n\n  .sanco-storage .sc-table thead th {\n    background: var(--sc-navy);\n    color: #ffffff;\n  }\n\n  .sanco-storage .sc-table tbody th {\n    background: var(--sc-pale);\n    font-weight: 600;\n  }\n\n  .sanco-storage .sc-table tbody td {\n    background: #ffffff;\n  }\n\n  .sanco-storage .sc-documents {\n    margin: 12px 0 20px;\n    padding-left: 22px;\n    background: transparent;\n    border: 0;\n    border-radius: 0;\n    box-shadow: none;\n  }\n\n  .sanco-storage .sc-documents li {\n    margin-bottom: 10px;\n  }\n\n  .sanco-storage a,\n  .sanco-storage a:visited {\n    color: #000000 !important;\n    text-decoration: underline !important;\n    text-decoration-color: #000000 !important;\n    text-decoration-thickness: 2px !important;\n    text-underline-offset: 3px;\n    overflow-wrap: anywhere;\n  }\n\n  .sanco-storage a:hover {\n    color: var(--sc-navy) !important;\n    text-decoration-color: var(--sc-green) !important;\n  }\n\n  .sanco-storage a:focus-visible {\n    outline: 2px solid var(--sc-navy);\n    outline-offset: 4px;\n  }\n\n  @media (hover: hover) and (pointer: fine) {\n    .sanco-storage .sc-table tbody tr:hover \u003e * {\n      background: var(--sc-hover);\n    }\n\n    @supports selector(table:has(th:hover)) {\n      .sanco-storage .sc-table:has(tr \u003e :nth-child(1):hover)\n        tbody tr \u003e :nth-child(1),\n      .sanco-storage .sc-table:has(tr \u003e :nth-child(2):hover)\n        tbody tr \u003e :nth-child(2) {\n        background: var(--sc-hover);\n      }\n    }\n  }\n\n  @media (max-width: 600px) {\n    .sanco-storage {\n      font-size: 15px;\n      line-height: 1.6;\n    }\n\n    .sanco-storage .sc-table {\n      font-size: 12.5px;\n    }\n\n    .sanco-storage .sc-table th,\n    .sanco-storage .sc-table td {\n      padding: 6px 7px;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"sanco-storage\"\u003e\n\u003ch2\u003e1,000 Gallon ASME Storage Tank – ECO-1000GLNSM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSANCO₂ ECO-1000GLNSM Storage Tank\u003c\/strong\u003e provides \u003cstrong\u003e1,000 gallons of actual hot water storage\u003c\/strong\u003e for commercial domestic hot water systems. Its \u003cstrong\u003eASME carbon steel vessel\u003c\/strong\u003e features a baked-on Ultonium porcelain enamel lining, magnesium anode corrosion protection, and \u003cstrong\u003eR16 insulation\u003c\/strong\u003e to help protect the tank against corrosion and reduce stored-water heat loss.\u003c\/p\u003e\n\u003cp\u003eThis vertical storage tank is designed for integration with \u003cstrong\u003eGS5-45HPC and GS5-45HPC-D heat pumps\u003c\/strong\u003e. Heat pumps, controls, and installation accessories must be specified separately as applicable.\u003c\/p\u003e\n\u003csection class=\"sc-section\"\u003e\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cdiv class=\"sc-table-wrap\"\u003e\n\u003ctable class=\"sc-table\" aria-label=\"ECO-1000GLNSM product highlights\"\u003e\n\u003ccolgroup\u003e \u003ccol class=\"sc-label\"\u003e \u003ccol class=\"sc-value\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank Construction\u003c\/th\u003e\n\u003ctd\u003eASME carbon steel vessel with baked-on Ultonium porcelain enamel lining.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage Volume — Actual \/ Nominal\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1,000 \/ 1,119 gallons\u003c\/strong\u003e, as labeled in the manufacturer submittal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrientation\u003c\/th\u003e\n\u003ctd\u003eVertical storage tank.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCorrosion Protection\u003c\/th\u003e\n\u003ctd\u003eGlass-lined interior. The specification table lists \u003cstrong\u003ethree magnesium anodes\u003c\/strong\u003e, while the drawing shows four anode connection locations. Confirm the supplied anode quantity with the manufacturer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eR16\u003c\/strong\u003e spray-applied foam, approximately \u003cstrong\u003e2¼ to 2½ inches thick\u003c\/strong\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExterior Finish\u003c\/th\u003e\n\u003ctd\u003eAcrylic topcoat over the insulation, with SANCO₂ stenciling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eManufacturer submittal permits interior and exterior installation. Site conditions and piping freeze protection must be addressed in the system design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible Heat Pumps\u003c\/th\u003e\n\u003ctd\u003eGS5-45HPC and GS5-45HPC-D, as identified in the exact-model submittal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"sc-section\"\u003e\n\u003ch2\u003eConnections \u0026amp; Controls\u003c\/h2\u003e\n\u003cdiv class=\"sc-table-wrap\"\u003e\n\u003ctable class=\"sc-table\" aria-label=\"ECO-1000GLNSM connections and controls\"\u003e\n\u003ccolgroup\u003e \u003ccol class=\"sc-label\"\u003e \u003ccol class=\"sc-value\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnection \/ Feature\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBuilding Cold Water Inlet\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e3-inch female NPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBuilding Hot Water Outlet\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e3-inch female NPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCold Water Supply to Heat Pump\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e1½-inch male NPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHot Water Return from Heat Pump\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e1½-inch female NPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Sensor Wells\u003c\/th\u003e\n\u003ctd\u003eLocated at the top, midpoint, and bottom of the tank. Drawing identifies \u003cstrong\u003e¾-inch NPT\u003c\/strong\u003e sensor connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDirect Heat Pump Sensor Control\u003c\/th\u003e\n\u003ctd\u003eFor the direct-control arrangement described in the submittal, each connected heat pump requires a field-installed \u003cstrong\u003e91101-45190 temperature sensor\u003c\/strong\u003e wired to that heat pump.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptional Multi-Unit Controller\u003c\/th\u003e\n\u003ctd\u003eWhen the \u003cstrong\u003eECO-CMB-BAC\u003c\/strong\u003e controller is used, its T1, T2, and T3 tank sensors are field-installed in the tank thermowells. Follow the approved controller wiring and system design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e\n\u003ctd\u003eDrawing shows a \u003cstrong\u003e1½-inch NPT\u003c\/strong\u003e drain. Construction notes also call for a drain connection in the cold water piping to the GS5 manifold.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterconnecting Piping\u003c\/th\u003e\n\u003ctd\u003ePipe sizes are determined by the system design. The submittal lists \u003cstrong\u003e66 ft maximum pipe length\u003c\/strong\u003e and \u003cstrong\u003e23 ft maximum vertical separation\u003c\/strong\u003e; confirm the measurement basis and approved layout with ECO₂ application engineering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"sc-section\"\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cdiv class=\"sc-table-wrap\"\u003e\n\u003ctable class=\"sc-table\" aria-label=\"ECO-1000GLNSM dimensions and weights\"\u003e\n\u003ccolgroup\u003e \u003ccol class=\"sc-label\"\u003e \u003ccol class=\"sc-value\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVessel Outside Diameter\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e54 inches\u003c\/strong\u003e, as shown in the drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulated Outside Envelope\u003c\/th\u003e\n\u003ctd\u003eApproximately \u003cstrong\u003e59 inches\u003c\/strong\u003e, reference dimension. Confirm final installation and shipping dimensions before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight References\u003c\/th\u003e\n\u003ctd\u003eDrawing marks \u003cstrong\u003e113 inches\u003c\/strong\u003e and a separate \u003cstrong\u003e121.50-inch reference dimension\u003c\/strong\u003e. Confirm reference points, headroom, and lifting clearance on the approved drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManway\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e12 × 16 inches\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLifting Lugs\u003c\/th\u003e\n\u003ctd\u003eTwo, as shown in the drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmpty Tank Weight\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e2,800 lb\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e3,500 lb\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eAllow access for anode service, sensors, the manway, and lifting equipment. Final support, anchorage, and service clearances must follow the approved installation design.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"sc-section\"\u003e\n\u003ch2\u003eSafety \u0026amp; Warranty\u003c\/h2\u003e\n\u003cdiv class=\"sc-table-wrap\"\u003e\n\u003ctable class=\"sc-table\" aria-label=\"ECO-1000GLNSM safety and warranty\"\u003e\n\u003ccolgroup\u003e \u003ccol class=\"sc-label\"\u003e \u003ccol class=\"sc-value\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Allowable Working Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e125 psi\u003c\/strong\u003e, per the dimensional drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e180°F\u003c\/strong\u003e, per the dimensional drawing. This is a tank limit, not a recommended fixture delivery temperature.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure Relief Valve\u003c\/th\u003e\n\u003ctd\u003eRequires a \u003cstrong\u003efield-supplied and field-installed, ASME-approved pressure relief valve\u003c\/strong\u003e set at \u003cstrong\u003e125 psig\u003c\/strong\u003e, connected to the tank’s \u003cstrong\u003e1¼-inch NPT relief connection\u003c\/strong\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelief Discharge\u003c\/th\u003e\n\u003ctd\u003eRelief valve discharge must be piped to a suitable location. Confirm the complete relief-device specification and installation requirements for the project.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank Warranty\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFive years\u003c\/strong\u003e, as stated in the June 2026 exact-model submittal. Detailed coverage and purchase\/installation eligibility require confirmation under the applicable manufacturer policy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"sc-section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eFor commercial domestic hot water storage in projects such as multifamily buildings, hotels, schools, and other facilities with substantial hot water demand. Final tank selection depends on peak demand, heat pump capacity, recirculation loads, installation conditions, and the approved system design.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"sc-section\"\u003e\n\u003ch2\u003eTechnical Documents\u003c\/h2\u003e\n\u003cul class=\"sc-documents\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/ECO-1000GLNSM-Tank-Submittal-06-2026.pdf?v=1793908234\" title=\"Tank Submittal\"\u003eECO-1000GLNSM Tank Submittal — June 2026\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/91101-45190-Tank-Temperature-Sensor-Submittal-04-2024.pdf?v=1793897978\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e 91101-45190 Tank Temperature Sensor Submittal \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/ECO_CMB_Installation_Guide_0825.pdf?v=1793897979\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Optional ECO-CMB-BAC Controller Installation Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/ECO_CMB_Program_Guide_0726.pdf?v=1793897979\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Optional ECO-CMB-BAC Controller Programming Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/CMB_BACnet_Points_0624.pdf?v=1793897978\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Optional ECO-CMB-BAC Controller BACnet Points List \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSensor and controller documents are supplemental system references. Controller guides apply when the optional ECO-CMB-BAC controller is specified.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Sanco2","offers":[{"title":"Default Title","offer_id":67909440569397,"sku":"ECO-1000GLNSM","price":44772.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/Screenshot_2025-09-11_134556-removebg-preview_65d8c9df-6271-4b59-a45a-94bebe17168b.png?v=1793910052","url":"https:\/\/plumbestore.com\/products\/sanco2-505-gallon-storage-tank-eco-1000glnsm","provider":"plumbEstore","version":"1.0","type":"link"}