{"product_id":"sauermann-h2s-sensor-230","title":"Sauermann H2S Sensor 230","description":"\u003cdiv class=\"clearfix text-formatted field field--name-field-ia-description field--type-text-long field--label-hidden field__item\"\u003e\n\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"request-6a3c0e42-52ec-83e8-985d-724a9f967eb8-13\" class=\"\"\u003e\n\u003csection data-turn=\"assistant\" data-testid=\"conversation-turn-30\" data-turn-id-container=\"request-6a3c0e42-52ec-83e8-985d-724a9f967eb8-13\" data-turn-id=\"request-6a3c0e42-52ec-83e8-985d-724a9f967eb8-13\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-conversation-screenshot-content=\"\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-turn-start-message=\"true\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-5\" dir=\"auto\" data-message-id=\"cac521ad-ba7d-4dcc-9600-aa0ad8ab2a6a\" data-message-author-role=\"assistant\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"46\" data-start=\"0\" data-section-id=\"aqqtve\"\u003e\u003cstrong\u003eSauermann CxHy 230 Sensor Upgrade\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"368\" data-start=\"41\"\u003eEnhance the functionality of your combustion analyzer with the \u003cstrong data-end=\"144\" data-start=\"104\"\u003eSauermann H₂S Sensor 230 Upgrade Kit\u003c\/strong\u003e. This genuine Sauermann upgrade kit includes an \u003cstrong data-end=\"262\" data-start=\"193\"\u003eelectrochemical Hydrogen Sulfide (H₂S) sensor and interface board\u003c\/strong\u003e, allowing users to add or replace H₂S measurement capability on the \u003cstrong data-end=\"367\" data-start=\"331\"\u003eSauermann Si-CA 230 Gas Analyzer\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"807\" data-start=\"370\"\u003eDesigned specifically for professional combustion analysis and industrial emissions monitoring, this OEM upgrade kit provides a hydrogen sulfide measuring range of \u003cstrong data-end=\"550\" data-start=\"534\"\u003e0 to 500 ppm\u003c\/strong\u003e, delivering accurate and reliable H₂S measurements in demanding applications. The included electronic interface board ensures seamless integration and straightforward installation, enabling technicians to quickly expand analyzer functionality in the field.\u003c\/p\u003e\n\u003cp data-end=\"1071\" data-start=\"809\"\u003eEngineered to Sauermann's exact specifications, the H₂S Sensor 230 Upgrade Kit helps maintain analyzer accuracy, maximize performance, and provide dependable gas measurements for service, commissioning, troubleshooting, and environmental compliance applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; margin-bottom: 30px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #003b71; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); text-align: left; width: 36.419%;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); text-align: left; width: 63.581%;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 36.419%;\"\u003e\u003cstrong\u003ePrecise H₂S Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 63.581%;\"\u003eAdvanced electrochemical technology provides accurate hydrogen sulfide measurements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 36.419%;\"\u003e\u003cstrong\u003eWide Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 63.581%;\"\u003eMeasures hydrogen sulfide concentrations from 0 to 500 ppm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 36.419%;\"\u003e\u003cstrong\u003eComplete Upgrade Solution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 63.581%;\"\u003eIncludes both the H₂S sensor and interface board for straightforward analyzer upgrades.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 36.419%;\"\u003e\u003cstrong\u003eInterchangeable Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 63.581%;\"\u003eDesigned for easy installation and seamless integration with the Si-CA 230 analyzer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 36.419%;\"\u003e\u003cstrong\u003eOEM Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 63.581%;\"\u003eGenuine Sauermann sensor and board engineered for optimum performance and long-term reliability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 36.419%;\"\u003e\u003cstrong\u003eMaintains Analyzer Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 63.581%;\"\u003eEnsures dependable combustion analysis and gas measurement results.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #003b71; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); text-align: left; width: 31.9541%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); text-align: left; width: 68.0459%;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eH₂S Sensor 230 Upgrade Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eElectrochemical Hydrogen Sulfide (H₂S) Sensor with Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eMeasured Gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eHydrogen Sulfide (H₂S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eH₂S Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003e0 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eH₂S Sensor and Electronic Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eSauermann Si-CA 230 Gas Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eField Upgrade \/ Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eSauermann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 31.9541%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 68.0459%;\"\u003eCombustion analysis, industrial gas monitoring, emissions testing, and advanced flue gas analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/Sauermann_H2S_Sensor_230.png?v=1782332268\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"clearfix text-formatted field field--name-field-ia-description field--type-text-long field--label-hidden field__item\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"plumbEstore","offers":[{"title":"Default Title","offer_id":45664041009205,"sku":"27531","price":1556.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/Sauermann_H2S_Sensor_230.png?v=1782332268","url":"https:\/\/plumbestore.com\/products\/sauermann-h2s-sensor-230","provider":"plumbEstore","version":"1.0","type":"link"}