{"product_id":"sunearth-custom-absorber-4x10-plate-1-1-2-hdr","title":"SunEarth Custom Absorber 4x10 Plate 1 1\/2 HDR","description":"\u003cp data-section-id=\"1fv3sxt\" data-start=\"0\" data-end=\"55\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eSunEarth Custom Absorber 4 x 10 Paint – 1½\" Header\u003c\/strong\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"56\" data-end=\"86\"\u003e\u003cstrong data-start=\"56\" data-end=\"86\"\u003ePart Number: CABS-P-40-1.5\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"1k8uwy3\" data-start=\"88\" data-end=\"111\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"113\" data-end=\"511\"\u003eThe \u003cstrong data-start=\"117\" data-end=\"187\"\u003eSunEarth Custom Absorber 4 x 10 Paint – 1½\" Header (CABS-P-40-1.5)\u003c\/strong\u003e is a premium replacement absorber plate engineered for high-performance commercial solar thermal systems. Built with SunEarth's proven \u003cstrong data-start=\"323\" data-end=\"366\"\u003eSunBurst all-copper absorber technology\u003c\/strong\u003e, this custom absorber maximizes solar energy collection while providing outstanding durability, corrosion resistance, and long-term reliability.\u003c\/p\u003e\n\u003cp data-start=\"513\" data-end=\"998\"\u003eConstructed from a heavy-duty \u003cstrong data-start=\"543\" data-end=\"591\"\u003e0.008-inch roll-formed copper absorber sheet\u003c\/strong\u003e continuously soldered to \u003cstrong data-start=\"617\" data-end=\"641\"\u003eType-M copper risers\u003c\/strong\u003e and \u003cstrong data-start=\"646\" data-end=\"679\"\u003e1½-inch Type-M copper headers\u003c\/strong\u003e, the CABS-P-40-1.5 is designed to deliver superior flow capacity for larger collector arrays and commercial applications. The semi-selective painted absorber coating enhances thermal performance, while the oversized headers help simplify system design by allowing higher flow rates and additional collectors in a bank.\u003c\/p\u003e\n\u003cp data-start=\"1000\" data-end=\"1469\"\u003eDesigned for \u003cstrong data-start=\"1013\" data-end=\"1052\"\u003e160 PSIG maximum operating pressure\u003c\/strong\u003e and hydrostatically tested to \u003cstrong data-start=\"1083\" data-end=\"1095\"\u003e400 PSIG\u003c\/strong\u003e, the CABS-P-40-1.5 provides an ideal solution for replacing aging absorber plates and extending the service life of existing solar thermal collectors. Available in custom sizes up to 14 feet long, SunEarth absorbers are manufactured to restore performance without replacing the complete collector.\u003c\/p\u003e\n\u003cp data-section-id=\"1ma7m6t\" data-start=\"1476\" data-end=\"1491\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1493\" data-end=\"2111\"\u003e\n\u003cli data-section-id=\"c9rire\" data-start=\"1493\" data-end=\"1537\"\u003ePremium SunBurst all-copper absorber plate\u003c\/li\u003e\n\u003cli data-section-id=\"wynrb6\" data-start=\"1538\" data-end=\"1578\"\u003eCustom 4 ft. × 10 ft. painted absorber\u003c\/li\u003e\n\u003cli data-section-id=\"1ha9fij\" data-start=\"1579\" data-end=\"1652\"\u003eOversized \u003cstrong data-start=\"1591\" data-end=\"1624\"\u003e1½-inch Type-M copper headers\u003c\/strong\u003e for commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"1qsgn2a\" data-start=\"1653\" data-end=\"1730\"\u003eSemi-selective painted absorber coating for excellent solar heat absorption\u003c\/li\u003e\n\u003cli data-section-id=\"1wdfwln\" data-start=\"1731\" data-end=\"1800\"\u003eContinuous soldered copper absorber sheet for maximum heat transfer\u003c\/li\u003e\n\u003cli data-section-id=\"wftqmv\" data-start=\"1801\" data-end=\"1829\"\u003eType-M copper riser tubing\u003c\/li\u003e\n\u003cli data-section-id=\"114g0kt\" data-start=\"1830\" data-end=\"1879\"\u003eMinimum 5% silver brazed header-to-riser joints\u003c\/li\u003e\n\u003cli data-section-id=\"100fc7u\" data-start=\"1880\" data-end=\"1930\"\u003eRated for operating pressures up to \u003cstrong data-start=\"1918\" data-end=\"1930\"\u003e160 PSIG\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dugvlh\" data-start=\"1931\" data-end=\"1971\"\u003eHydrostatically tested to \u003cstrong data-start=\"1959\" data-end=\"1971\"\u003e400 PSIG\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n7sp81\" data-start=\"1972\" data-end=\"2006\"\u003eUV-resistant copper construction\u003c\/li\u003e\n\u003cli data-section-id=\"qgv3u3\" data-start=\"2007\" data-end=\"2073\"\u003eDesigned for replacement of existing commercial solar collectors\u003c\/li\u003e\n\u003cli data-section-id=\"1r0dhzd\" data-start=\"2074\" data-end=\"2111\"\u003eManufactured in the USA by SunEarth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1cgu054\" data-start=\"1354\" data-end=\"1381\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/SunEarth_4x10_Custom_Plate.png?v=1783010788\"\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"mu966k\" data-start=\"1833\" data-end=\"1848\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1850\" data-end=\"1886\"\u003e\u003cstrong\u003eThe SunEarth CABS-P-40-1.5 is ideal for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1888\" data-end=\"2096\"\u003e\n\u003cli data-section-id=\"9h3fn9\" data-start=\"1888\" data-end=\"1922\"\u003eSolar domestic hot water systems\u003c\/li\u003e\n\u003cli data-section-id=\"hc550a\" data-start=\"1923\" data-end=\"1955\"\u003eCommercial solar water heating\u003c\/li\u003e\n\u003cli data-section-id=\"8pjyro\" data-start=\"1956\" data-end=\"1992\"\u003eMulti-family solar thermal systems\u003c\/li\u003e\n\u003cli data-section-id=\"142mpr0\" data-start=\"1993\" data-end=\"2021\"\u003eIndustrial process heating\u003c\/li\u003e\n\u003cli data-section-id=\"1gkixzw\" data-start=\"2022\" data-end=\"2053\"\u003eSolar collector refurbishment\u003c\/li\u003e\n\u003cli data-section-id=\"182wk25\" data-start=\"2054\" data-end=\"2096\"\u003eReplacement absorber plate installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1cgu054\" data-start=\"2103\" data-end=\"2130\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3207\" data-start=\"2431\"\u003e\n\u003cthead data-end=\"2458\" data-start=\"2431\"\u003e\n\u003ctr data-end=\"2458\" data-start=\"2431\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2447\" data-start=\"2431\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"md\" data-end=\"2458\" data-start=\"2447\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3207\" data-start=\"2486\"\u003e\n\u003ctr data-end=\"2513\" data-start=\"2486\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2501\" data-start=\"2486\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-end=\"2513\" data-start=\"2501\" data-col-size=\"md\"\u003eSunEarth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2543\" data-start=\"2514\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2524\" data-start=\"2514\"\u003eProduct\u003c\/td\u003e\n\u003ctd data-end=\"2543\" data-start=\"2524\" data-col-size=\"md\"\u003eCustom Absorber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2575\" data-start=\"2544\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2558\" data-start=\"2544\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2575\" data-start=\"2558\"\u003eCABS-P-40-1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2635\" data-start=\"2576\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2590\" data-start=\"2576\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-end=\"2635\" data-start=\"2590\" data-col-size=\"md\"\u003eCustom 4 × 10 Paint Absorber – 1½\" Header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2669\" data-start=\"2636\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2651\" data-start=\"2636\"\u003eOverall Size\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2669\" data-start=\"2651\"\u003e4 ft. × 10 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2711\" data-start=\"2670\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2683\" data-start=\"2670\"\u003eGross Area\u003c\/td\u003e\n\u003ctd data-end=\"2711\" data-start=\"2683\" data-col-size=\"md\"\u003eApproximately 40 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2754\" data-start=\"2712\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2732\" data-start=\"2712\"\u003eAbsorber Material\u003c\/td\u003e\n\u003ctd data-end=\"2754\" data-start=\"2732\" data-col-size=\"md\"\u003eRoll-Formed Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2790\" data-start=\"2755\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2773\" data-start=\"2755\"\u003eHeader Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2790\" data-start=\"2773\"\u003eType-M Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2815\" data-start=\"2791\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2805\" data-start=\"2791\"\u003eHeader Size\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2815\" data-start=\"2805\"\u003e1½ in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2850\" data-start=\"2816\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2833\" data-start=\"2816\"\u003eRiser Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2850\" data-start=\"2833\"\u003eType-M Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2886\" data-start=\"2851\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2864\" data-start=\"2851\"\u003eRiser Size\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2886\" data-start=\"2864\"\u003e½ in. O.D. Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2932\" data-start=\"2887\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2897\" data-start=\"2887\"\u003eCoating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2932\" data-start=\"2897\"\u003eSemi-Selective Painted Absorber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2974\" data-start=\"2933\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2962\" data-start=\"2933\"\u003eMaximum Operating Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2974\" data-start=\"2962\"\u003e160 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3015\" data-start=\"2975\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3003\" data-start=\"2975\"\u003eHydrostatic Test Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3015\" data-start=\"3003\"\u003e400 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3093\" data-start=\"3016\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3031\" data-start=\"3016\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-end=\"3093\" data-start=\"3031\" data-col-size=\"md\"\u003eContinuous soldered copper plate with silver-brazed joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3137\" data-start=\"3094\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3121\" data-start=\"3094\"\u003eMaximum Length Available\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3137\" data-start=\"3121\"\u003eUp to 14 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3207\" data-start=\"3138\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3152\" data-start=\"3138\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3207\" data-start=\"3152\"\u003eCommercial Replacement Solar Thermal Absorber Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-section-id=\"1cgu054\" data-start=\"1354\" data-end=\"1381\" class=\"PDq2pG_selectionAnchorContainer\"\u003e \u003c\/p\u003e\n\u003cp data-section-id=\"1cgu054\" data-start=\"1354\" data-end=\"1381\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eTechnical Documents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-ved=\"2ahUKEwiP1NmOrrKVAxWfMTQIHQaSASIQi4wTegoIAggACAEIBBAA\" data-copy-service-computed-style='font-family: \"Google Sans\", Roboto, Arial, sans-serif; font-size: 16px; font-weight: 400; margin: 0px; text-decoration: none; border-bottom: 0px rgb(10, 10, 10);'\u003e\n\u003cp style=\"padding-left: 40px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/SunEarth_2026_catalog.pdf?v=1782940446\" title=\"SunEarth Product Catalog\"\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sun Earth","offers":[{"title":"Default Title","offer_id":45690911326261,"sku":"CABS-P-40-1.5","price":2997.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2380\/1317\/files\/SunEarth_4x10_Custom_Plate.png?v=1783010788","url":"https:\/\/plumbestore.com\/products\/sunearth-custom-absorber-4x10-plate-1-1-2-hdr","provider":"plumbEstore","version":"1.0","type":"link"}