            Vents Bucket Fan Series (Destratification Fans) – Models 420, 1055 & 1460
 Most Items Ship Same Day 
        
      
      (Warranty, Return and Refunds)
         Most Items Ship Same Day 
        
      
      (Warranty, Return and Refunds)
      
          
    
    Bucket Fan Series (Destratification Fans) – Models 420, 1055 & 1460
Airflow Capacity: Up to 1,460 CFM
Efficiency: Reduces energy costs & increases comfort
Durability: Steel casing with a high-quality, corrosion-resistant finish
Design: Attractive appearance, quiet operation, speed-controllable, and easy to install
Performance: Outlet directing vanes provide a long, linear airflow
Reliability: Asynchronous motor with ball bearings and thermal protection ensures safe, smooth operation
🏭 Ideal Applications
- 
Big box stores 
- 
Shopping malls 
- 
Warehouses 
- 
Greenhouses 
- 
Athletic facilities 
- 
Grocery stores 
- 
Industrial buildings 
- 
Distribution centers 
- 
Atriums 
- 
Gymnasiums 
⚡ Energy Savings Through Destratification
Cold Weather:
- 
In tall buildings, temperature typically rises 0.5°F to 1°F for every foot of height. 
- 
A 20 ft facility may be 10–20°F hotter at the ceiling than at the floor. 
- 
Bucket Fans push superheated ceiling air to the floor, cutting heating bills by 25–33%. 
Hot Weather:
- 
In air-conditioned buildings, cold air from ceiling ductwork often loses efficiency battling rising warm air. 
- 
Up to 40% of input energy is wasted pumping excess cold air to overcome stratification. 
- 
Placing Bucket Fans near cold air registers pushes conditioned air where it’s needed most, lowering cooling costs. 
✅ Rule of Thumb: Turn the air 1–2 times per hour for full destratification benefits.
📏 Sizing the Right Bucket Fan
- 
Ceiling heights 20–30 ft: Use Bucket Fan 420 
- 
Ceiling heights 25–35 ft: Use Bucket Fan 1055 
- 
Ceiling heights 30–45 ft: Use Bucket Fan 1460 
Example Calculation:
Building dimensions = 125 ft (L) × 75 ft (W) × 20 ft (H) = 187,500 cu. ft
Formula:
- 
H × W × L = Air Volume (V) 
- 
V ÷ CFM ÷ 60 = Number of Fans 
187,500 ÷ 1055 ÷ 60 = 2.96 fans → 3 Bucket Fans required (always round up).
🔎 Model Options
| Model | Airflow Capacity | Power Consumption | Sound Level | Weight | 
|---|---|---|---|---|
| Bucket Fan 420 | Up to 420 CFM | Up to 60 W | Up to 3.5 Sones | 24.3 lbs | 
| Bucket Fan 1055 | Up to 1055 CFM | Up to 94 W | Up to 4.3 Sones | 32 lbs | 
| Bucket Fan 1460 | Up to 1460 CFM | Up to 162 W | Up to 5.6 Sones | 37.5 lbs | 