ARCTIC-AIRHANDLER-COOLINIG-1750

Hydronic Air Handlers – Central Heating & Cooling
Hydronic air handlers are designed to transfer energy from hydronic boilers and A/C units throughout your space using centralized ductwork. While traditional models have been around for years, the Arctic Hydronic Air Handlers represent a new generation of efficiency and advanced technology.
❄️ Advanced Heating & Cooling for Heat Pumps
Arctic hydronic air handlers are specifically engineered for heat pumps, geothermal systems, and condensing boilers, which perform best at lower temperatures. With variable frequency drive (VFD) technology and oversized 6-row heat exchangers, Arctic sets a new standard for efficient comfort.
🔑 Key Features of Arctic Hydronic Air Handlers
-
6-Row Hydronic Copper & Aluminum Heat Exchangers
-
Nearly 400% larger than typical air handler coils
-
Maximizes heat transfer at lower water temperatures
-
Works seamlessly with low-temp systems and traditional high-temp boilers (up to 150,000 BTU @ 190°F)
-
Special internal loop design ensures low pressure drop (3.1 ft head @ 10 GPM)
-
-
3-Phase Direct Drive Motors with VFD
-
No start-up capacitor needed → ultra-quiet and efficient
-
Adjusts speed dynamically, only using the energy required
-
Delivers up to 1,750 CFM of airflow
-
-
WAG Variable Speed Drive Controller
-
Converts 120V single-phase power to efficient 3-phase
-
Uses less than 100 watts on constant fan speed
-
Easy-touch settings for cooling, heating, and fan-only modes
-
Automatically adjusts fan speed based on static pressure (dirty filters, closed vents, zoning changes, etc.)
-
📊 Performance & Sizing
-
Arctic LV-Z-1750 → 3.5 to 5 tons heating/cooling
-
Arctic LV-Z-1050 → 1.5 to 3 tons heating/cooling
The built-in static pressure sensor automatically sets the optimum fan speed for your home’s ductwork. This makes manual fan sizing unnecessary while reducing energy use and fan noise.
🏠 Zoning with Arctic Hydronic Air Handlers
With VFD technology, Arctic hydronic air handlers make zoning simple:
-
Individual thermostats control zone dampers.
-
When one zone closes, static pressure increases.
-
The air handler senses the change and reduces RPM, lowering airflow (CFM) and saving energy.
This eliminates wasted power and excess fan noise compared to traditional furnaces that run at a constant speed regardless of demand.
✅ Why Choose Arctic Hydronic Air Handlers?
-
Optimized for heat pumps, geothermal, and condensing boilers
-
Ultra-efficient operation with VFD and oversized coil
-
Flexible installation with automatic fan speed adjustment
-
Zoning capability for personalized comfort and energy savings