Senville SENTC Top-Discharge Central Heat Pump Systems | 2–5 Ton
Senville SENTC Top-Discharge Central Heat Pump Systems | 2–5 Ton - 24000 BTU 2 Ton / 16Ft / None is backordered and will ship as soon as it is back in stock.
Product availability changes quickly. Contact our customer service to confirm availability and lead time before purchasing. Email support@plumbestore.com or call 888-615-0755
System Configuration and Auxiliary Heat
Choose a 2-, 3-, 4-, or 5-ton Senville SENTC top-discharge central heat pump system with a 16-ft or 50-ft line set. Under Auxiliary Heat, select None, 5 kW, 10 kW, 15 kW, or 20 kW. Configurations with auxiliary heat include an electric heater kit for supplemental heating.
Description
The Senville SENTC-TD Top-Discharge Central Heat Pump Series provides ducted heating and cooling in 2, 3, 4, and 5 ton nominal sizes. Each configuration listed here includes a matched indoor air handler and outdoor heat-pump condenser, with a choice of 16 ft or 50 ft installation kit and no auxiliary electric heater or 5 kW, 10 kW, 15 kW, or 20 kW Aux Heater. Configurations with auxiliary heat include an electric heater kit for supplemental heating.
Inverter technology adjusts system output to heating and cooling demand. The series uses R-32 refrigerant and 208/230V, 60 Hz, single-phase power. Senville publishes outdoor heating operation down to −4°F / −20°C. Select the system size using a professional building-load calculation and duct assessment.
Key Features
- Matched indoor air handler and outdoor top-discharge heat pump.
- Central ducted heating and cooling from one system.
- Variable-capacity DC inverter operation.
- Four nominal sizes from 24,000 to 60,000 BTU/h.
- Cooling efficiency up to 20.0 SEER2, depending on system size.
- Choice of 16 ft or 50 ft installation kit.
| Feature | Details |
|---|---|
| Manufacturer / series | Senville / SENTC-TD |
| System type | Matched ducted central heat pump system |
| Outdoor configuration | Top discharge |
| Refrigerant | R-32 |
| Power supply | 208/230V, 60 Hz, single phase |
| Outdoor heating range | −4°F to 75°F |
| Outdoor cooling range | 5°F to 131°F |
| Liquid / gas line sizes | 3/8 in. / 3/4 in. |
Capacity, Efficiency & Dimensions
BTU values in the column headings identify nominal system sizes. Rated capacities appear separately. Dimensions are width × depth × height. Weights are equipment net weights, not shipping or palletized weights.
2 & 3 Ton Systems
| Specification | 24,000 BTU/h 2 Ton |
36,000 BTU/h 3 Ton |
|---|---|---|
| Capacity & Efficiency | ||
| Model family | SENTC-24TD | SENTC-36TD |
| Rated cooling (BTU/h) | 24,000 | 34,000 |
| Rated heating (BTU/h) | 24,000 | 36,000 |
| SEER2 | 20.0 | 18.6 |
| EER2 | 13.3 | 11.7 |
| HSPF2 (Region IV) | 9.4 | 9.0 |
| Indoor Air Handler | ||
| Width (in.) | 21-1/32 | 21-1/32 |
| Depth (in.) | 21-1/32 | 21-1/32 |
| Height (in.) | 49-7/32 | 49-7/32 |
| Net weight (lb) | 125 | 137 |
| Outdoor Heat Pump | ||
| Width (in.) | 29-9/64 | 29-9/64 |
| Depth (in.) | 29-9/64 | 29-9/64 |
| Height (in.) | 25 | 25 |
| Net weight (lb) | 143 | 143 |
4 & 5 Ton Systems
| Specification | 48,000 BTU/h 4 Ton |
60,000 BTU/h 5 Ton |
|---|---|---|
| Capacity & Efficiency | ||
| Model family | SENTC-48TD | SENTC-60TD |
| Rated cooling (BTU/h) | 47,000 | 55,000 |
| Rated heating (BTU/h) | 50,000 | 57,000 |
| SEER2 | 17.6 | 17.7 |
| EER2 | 11.3 | 8.6 |
| HSPF2 (Region IV) | 9.1 | 8.0 |
| Indoor Air Handler | ||
| Width (in.) | 24-31/64 | 24-31/64 |
| Depth (in.) | 21-1/32 | 21-1/32 |
| Height (in.) | 52-63/64 | 52-63/64 |
| Net weight (lb) | 164 | 164 |
| Outdoor Heat Pump | ||
| Width (in.) | 29-9/64 | 29-9/64 |
| Depth (in.) | 29-9/64 | 29-9/64 |
| Height (in.) | 32-7/8 | 32-7/8 |
| Net weight (lb) | 187 | 187 |
Installation Kit Options
These SKUs identify configurations with no auxiliary electric heater.
| System size | 16 ft kit SKU | 50 ft kit SKU |
|---|---|---|
| 24,000 BTU/h / 2 Ton | SENTC-24TD-16 | SENTC-24TD-50 |
| 36,000 BTU/h / 3 Ton | SENTC-36TD-16 | SENTC-36TD-50 |
| 48,000 BTU/h / 4 Ton | SENTC-48TD-16 | SENTC-48TD-50 |
| 60,000 BTU/h / 5 Ton | SENTC-60TD-16 | SENTC-60TD-50 |
50 ft kit: A 50 ft communication wire is not included and must be supplied separately. Your installer must confirm piping length, any additional refrigerant requirements, and the correct communication wiring for the selected configuration.
What Comes with the System
| Item | Included equipment |
|---|---|
| Indoor unit | Matched ducted air handler |
| Outdoor unit | Top-discharge inverter heat-pump condenser |
| Installation kit | 16 ft or 50 ft kit, according to the selected SKU |
| Auxiliary electric heater | Not included in the eight configurations listed here |
Professional installation is required. Have a qualified HVAC contractor confirm the building load, ductwork, electrical service, equipment clearances, refrigerant piping, and commissioning requirements.
Product Highlights
- Four system sizes for professionally designed central duct installations.
- Matched indoor and outdoor equipment for heating and cooling.
- Compact top-discharge outdoor configuration.
- Two installation-kit lengths to suit the planned equipment layout.
- Optional supplemental electric heat requires separate selection and compatibility confirmation.
Limited Warranty
Senville provides a limited manufacturer warranty, subject to the applicable coverage periods, installation requirements, conditions, and exclusions. Installation must be completed by a licensed HVAC professional. Labor and service-call costs are not covered. Refer to the full Senville Manufacturer Warranty and the documentation supplied with your system for complete terms.
Technical Documents
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.