Arctic Titanium Heat Pump for Swimming Pools and Spas - 025ZA/B-R32

  • $3,350.25


  Most Items Ship Same Day   (Warranty, Return and Refunds)

Arctic 025ZA/B-R32 Heat Pump – Heat & Chill Your Hot Tub, Spa, or Pool

🔥 Chiller and Heater in One!
While hot tub users often focus on heating, the Arctic Heat Pump can also chill your water when needed. Simply select the mode on the controller to heat or cool. Perfect for hot climates, sauna enthusiasts, or anyone wanting a cold plunge tub. Cold water therapy has many health benefits and is gaining popularity in North America, following centuries-old Nordic traditions.

🌡️ Heating & Cooling Performance

  • Operates down to -4°F (-20°C), making it the most efficient cold-weather heat pump available

  • Heats and cools with over 80% energy savings compared to traditional heating equipment

  • Produces up to 11 kW / 37,532 BTU of heat energy

  • Works up to 104°F even when ambient temperature is 20°F

  • Ideal for hot tubs, spas, smaller pools, and swim spas

⚙️ Key Features

  • Three modes: Heating, Cooling, Auto

  • Includes Heat Pump Digital Controller and optional WiFi Remote Control

  • Double Rotor DC Inverter Compressor for superior efficiency

  • Spiral Titanium Heat Exchanger

  • Ultra-quiet DC Brushless Fan Motor with sound insulation

  • High-Efficiency Fin Heat Exchanger

  • Vibration pads included for stable, quiet operation

  • Built-in hot gas defrost and drain pan/compressor freeze protection

  • TUV Rheinland certified for North American installations

  • Easy installation with no refrigeration mechanic needed

  • Operating Temperature Range: -4°F (-20°C) to 113°F (45°C)

📊 Technical Specs

  • Water connections: 1.5"

  • Max Amps: 11.2

  • Voltage: 220-240 VAC

  • Output: 11 kW (37,532 BTU)

  • Weight: 288 lbs (131 kg)

  • Flow rate: 27.10 GPM (pool pump sold separately)

  • Dimensions: 51" H x 21" W x 52" D

How It Works
The Arctic Heat Pump harnesses energy from the air. Using an oversized evaporator, energy is removed and transferred to the refrigerant. The compressor compresses the gas, increasing its temperature. Hot gas passes through a titanium heat exchanger, transferring energy to your pool or spa water. In cooling mode, the cycle reverses to chill the water.
The unit consumes 1/3 to 1/5 the electricity of its heating capacity, saving up to 80% compared to traditional electric or gas heaters. Built-in hot gas defrost and freeze protection ensure reliable cold-weather performance.

🛡️ Warranty & Support

  • 1-year warranty on all parts and 2-year warranty on the compressor

  • Next business day replacement (subject to shipping and inventory availability)

  • Lifetime technical support for all owners

  • Covers failures during normal operation or manufacturer defects

  • Does not cover failures due to incorrect installation, physical damage, or inappropriate operation

 Model  ARCTIC 25ZA/B 040ZA/B 060ZA/B
 Power Supply V/PH/Hz 220/1/50 (60) 220/1/50 (60) 220/1/50 (60)
Heating Capacity
Ranger
kW 2.75~11 4.38~17.5 6.45~25.8
BTU/h 9383~37532 14928~59710 22007~88030
COP Ranger W/W 3.6~13 3.6~13 3.6~13
Heating Capacity (1) kW 11.0 17.5 25.8
BTU/h 37532 59710 88030
COP (1)  A:30/W:28 W/W 6.2 6.2 6.2
Input Power (1) kW 1.77 2.82 4.16
Input Current (1) A 8.1 12.8 18.9
Heating Capacity (2) kW 11.0 17.5 25.8
BTU/h 37532 59710 88030
COP (2)  A:24/W:28 W/W 5.60 5.60 5.60
Input Power (2) kW 1.96 3.13 4.61
Input Current (2) A 8.9 14.2 20.9
Heating Capacity (3) kW 11.0 17.5 25.8
BTU/h 37532 59710 88030
COP (3)  A:15/W:28 W/W 4.8 4.8 4.8
Input Power (3)  kW 2.29 3.65 5.38
Input Current (3) A 10.4 16.6 24.4
Heating Capacity (4) kW 10.0 16.7 23.5
BTU/h 34120 56980 80182
COP (4)  A:7/W:28 W/W 4.2 4.2 4.2
Input Power (4) kW 2.38 3.98 5.60
Input Current (4) A 10.8 18.1 25.4
Heating Capacity (5) kW 9.2 14.4 21.0
BTU/h 31390 49133 71652
COP (5)  A:0/W:28 W/W 3.72 3.72 3.72
Input Power (5) kW 2.47 3.87 5.65
Input Current (5) A 11.2 17.6 25.7
Heating Capacity (6) kW 7.5 12.0 18.0
BTU/h 25590 40944 61416
COP (6)  A:-7/W:28 W/W 3.16 3.16 3.16
Input Power (6) kW 2.37 3.80 5.70
Input Current (6) A 10.8 17.3 25.9
 Compressor   TWIN Rotary TWIN Rotary TWIN Rotary
 Compressor Qty   1 1 1
 Fan Qty   1 1 1
 Noise dB(A) 52 54 54
 Water Outlet/Water Inlet inch 1–1/2" 1–1/2" 1–1/2"
 Water Flow Volume GPM 11.30 17.20 27.10
 Water Pressure Drop PSI 2.2 2.2 2.3
 Fan Direction   horizontal horizontal horizontal
 Refrigerant Type   R-32 R-32 R-32
 Unit Net Dimensions (L/M/H) mm 1115/470/700 1115/470/945 1195/470/1285
 Unit Shipping Dimensions (L/M/H) mm 1205/525/725 1205/525/975 1285/525/1315
 Net Weight kg 90 108 121
 Shipping Weight kg 96 116 131


Technical Documents

Read more...
shop pay installments buy now pay later
(Open hours: 9:00 AM - 5:00 PM)

Disclaimer: Must be installed by a licensed contractor or warranty is void.

Questions?


Speak with an expert
1-888-615-0755



We Also Recommend