SANCO2 505 Gallon Storage Tank ECO-675GLNSM
SANCO2 505 Gallon Storage Tank ECO-675GLNSM is backordered and will ship as soon as it is back in stock.
675 Gallon ASME Storage Tank – ECO-675GLNSM
The SANCO₂ ECO-675GLNSM Storage Tank provides 675 gallons of actual hot water storage for commercial domestic hot water systems. Its ASME carbon steel vessel features a baked-on Ultonium porcelain enamel lining, three magnesium anodes, and R16 insulation to help protect the tank against corrosion and reduce stored-water heat loss.
This vertical storage tank is designed for integration with GS5-45HPC and GS5-45HPC-D heat pumps. Heat pumps, controls, and installation accessories must be specified separately as applicable.
Product Highlights
| Feature | Details |
|---|---|
| Tank Construction | ASME carbon steel vessel with baked-on Ultonium porcelain enamel lining. |
| Storage Volume — Actual / Nominal | 675 / 752 gallons, as labeled in the manufacturer submittal. |
| Orientation | Vertical storage tank. |
| Corrosion Protection | Glass-lined interior and three magnesium anodes. |
| Insulation | R16 spray-applied foam, approximately 2¼ to 2½ inches thick. |
| Exterior Finish | Acrylic topcoat over the insulation, with SANCO₂ stenciling. |
| Installation Location | Manufacturer submittal permits interior and exterior installation. Site conditions and piping freeze protection must be addressed in the system design. |
| Compatible Heat Pumps | GS5-45HPC and GS5-45HPC-D, as identified in the exact-model submittal. |
Connections & Controls
| Connection / Feature | Details |
|---|---|
| Building Cold Water Inlet | 3-inch female NPT |
| Building Hot Water Outlet | 3-inch female NPT |
| Cold Water Supply to Heat Pump | 1½-inch male NPT |
| Hot Water Return from Heat Pump | 1½-inch female NPT |
| Temperature Sensor Wells | Located at the top, midpoint, and bottom of the tank. Drawing identifies ¾-inch NPT sensor connections. |
| Direct Heat Pump Sensor Control | For the direct-control arrangement described in the submittal, each connected heat pump requires a field-installed 91101-45190 temperature sensor wired to that heat pump. |
| Optional Multi-Unit Controller | When the ECO-CMB-BAC controller is used, its T1, T2, and T3 tank sensors are field-installed in the tank thermowells. Follow the approved controller wiring and system design. |
| Drain | Drawing shows a 1½-inch NPT drain. Construction notes also call for a drain connection in the cold water piping to the GS5 manifold. |
| Interconnecting Piping | Pipe sizes are determined by the system design. The submittal lists 66 ft maximum pipe length and 23 ft maximum vertical separation; confirm the measurement basis and approved layout with ECO₂ application engineering. |
Dimensions & Weights
| Specification | Details |
|---|---|
| Vessel Outside Diameter | 48 inches, as shown in the drawing. |
| Insulated Outside Envelope | Approximately 53 inches, reference dimension. Confirm final installation and shipping dimensions before ordering. |
| Height References | Drawing marks 96 inches OAH and a separate 104.50-inch reference dimension. Confirm reference points, headroom, and lifting clearance on the approved drawing. |
| Manway | 12 × 16 inches |
| Lifting Lugs | Two, as shown in the drawing. |
| Empty Tank Weight | 1,600 lb |
| Shipping Weight | 1,950 lb |
Allow access for anode service, sensors, the manway, and lifting equipment. Final support, anchorage, and service clearances must follow the approved installation design.
Safety & Warranty
| Specification | Details |
|---|---|
| Maximum Allowable Working Pressure | 125 psi, per the dimensional drawing. |
| Maximum Operating Temperature | 180°F, per the dimensional drawing. This is a tank limit, not a recommended fixture delivery temperature. |
| Pressure Relief Valve | Requires a field-supplied and field-installed, ASME-approved pressure relief valve set at 125 psig, connected to the tank’s 1¼-inch NPT relief connection. |
| Relief Discharge | Relief valve discharge must be piped to a suitable location. Confirm the complete relief-device specification and installation requirements for the project. |
| Tank Warranty | Five years, as stated in the June 2026 exact-model submittal. Detailed coverage and purchase/installation eligibility require confirmation under the applicable manufacturer policy. |
Applications
For commercial domestic hot water storage in projects such as multifamily buildings, hotels, schools, and other facilities with substantial hot water demand. Final tank selection depends on peak demand, heat pump capacity, recirculation loads, installation conditions, and the approved system design.
Technical Documents
-
ECO-675GLNSM Tank Submittal — June 2026
- 91101-45190 Tank Temperature Sensor Submittal
- Optional ECO-CMB-BAC Controller Installation Guide
- Optional ECO-CMB-BAC Controller Programming Guide
- Optional ECO-CMB-BAC Controller BACnet Points List
Sensor and controller documents are supplemental system references. Controller guides apply when the optional ECO-CMB-BAC controller is specified.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.