Free help & advice support@plumbestore.com

  • Free basic shipping over $35

    LTL freight charges may apply

  • Free help & advice

    Questions welcome!

  • Stock items ship same day

    For orders before 1pm CST

  • Open Mon-Fri

    9AM-5PM CST

Sanco2  |  SKU: ECO-45MDU-2H

SANCO₂ 4.5 kW Commercial Module Heat Pump Water Heater Systems

Regular price $12,949.30
Shipping calculated at checkout.
Heat Pumps

SANCO₂ Commercial Module Heat Pump Water Heater System – 4.5 kW Units

The SANCO₂ Commercial Module Heat Pump Water Heater System – 4.5 kW Units is a pre-engineered commercial water-heating solution designed to combine multiple SANCO₂ heat pumps into a scalable system for larger domestic hot water applications. The configurations described in this listing combine 2 to 4 heat pumps using 4.5 kW units, helping contractors and system designers match capacity to project demand.

Built around SANCO₂’s fifth-generation CO₂ heat pump technology, the system uses R744 natural refrigerant and is designed for operation in ambient temperatures as low as -25°F. The heat pump platform incorporates an inverter compressor, DC fan and water pump, and a gas cooler to support efficient heat transfer and commercial water-heating performance.

The 4.5 kW rating applies to each heat pump, not the combined module. Total nominal capacity is 9.0 kW for two units, 13.5 kW for three units, and 18.0 kW for four units.

SANCO₂ commercial systems can be paired with storage tanks, swing tanks, buffer tanks, controls, freeze protection, mounting materials, and other accessories as needed for the application. The manufacturer also offers a commercial system controller with capabilities including system staging, BACnet, cloud access, and load shifting.

Key Features

  • Pre-engineered SANCO₂ commercial module platform.
  • Configurable with 2–4 heat pumps.
  • Available with 4.5 kW heat pump units.
  • Uses R744 natural CO₂ refrigerant.
  • Designed to operate in ambient temperatures down to -25°F.
  • Fifth-generation heat pump technology.
  • Inverter compressor helps match operation to system demand.
  • DC fan and water pump operate based on load requirements.
  • Gas cooler supports efficient heat transfer from CO₂ refrigerant to water.
  • Compatible with commercial storage tanks, swing tanks, buffer tanks, controls, and accessories.
  • Optional commercial controller supports system staging, BACnet, cloud access, and load shifting.
  • Modular design supports a wide range of commercial domestic hot water applications.

Product Highlights

  • Pre-Engineered Commercial Module
  • Scalable 2–4 Heat Pump Design
  • 4.5 kW Modular Heat Pump Platform
  • Natural CO₂ Refrigerant Technology
  • Cold-Climate Operation Down to -25°F
  • High-Efficiency Fifth-Generation Design
  • Flexible Commercial System Configurations
  • Compatible with Multiple Storage Tank Sizes
  • Optional Smart Commercial Controls
  • Designed for High-Demand Domestic Hot Water Applications

SANCO₂ Commercial System Information

Commercial module operation and capabilities
Topic Customer Information
How the System Works SANCO₂ commercial systems use one or more heat pumps together with storage tanks and controls to produce and store domestic hot water. The modular design allows the system to be sized around the building’s hot water demand.
Heat Pump Options SANCO₂ commercial systems are offered with 4.5 kW pump options. The SANCO₂ Module is a pre-engineered kit that combines 2–4 heat pumps using 4.5 kW units.
Cold Climate Operation SANCO₂ heat pumps are designed to operate in outdoor ambient temperatures down to -25°F.
Refrigerant SANCO₂ uses natural CO₂ refrigerant, which the manufacturer identifies as having a low global warming potential.
Heat Pump Technology The fifth-generation SANCO₂ platform uses an inverter compressor, DC fan, DC water pump, and gas cooler to support efficient water heating.
Commercial Controls An optional SANCO₂ commercial controller supports system staging, BACnet, cloud access, and load shifting.
Module Recovery Rate Recovery must be confirmed for the selected heat pump quantity, inlet and outlet water temperatures, and outdoor conditions. The broader module-family recovery range does not specify the performance of each 2–4-unit configuration.
Heating COP COP — configuration-specific verification required; consult the approved performance data for the selected module and test conditions.
System Accessories Commercial systems can include freeze protection, mounting materials, controllers, tanks, and other accessories depending on the project design.
System Layout SANCO₂ systems can be designed around different heat pump and tank layouts. Layout and piping should be selected based on available space and project requirements.
System Scalability Multiple heat pumps and storage options allow SANCO₂ commercial systems to be configured for different commercial hot water demands.

Choosing the Right SANCO₂ System

Commercial system selection considerations
Selection Consideration What to Consider
Hot Water Demand Determine how much hot water the facility uses each day. SANCO₂ recommends using this demand to help determine the number of heat pumps and storage tanks required.
Heat Pump Quantity Select the number and capacity of heat pumps needed to meet the site's hot water demand while considering layout and installation requirements.
Storage Tank Capacity Select storage capacity based on daily usage, peak demand, and system design.
Swing Tank Evaluate recirculation loads and delivery-temperature requirements with the manufacturer to determine whether a swing tank is required.
Buffer Tank Confirm piping length, elevation, and buffer-tank requirements with the manufacturer’s commercial design team. Follow the approved project piping design.
Horizontal vs. Vertical Layout Choose the module arrangement that best fits the available installation space and project design.
Controls & Building Integration Consider whether the project requires BACnet connectivity, system staging, cloud access, or load shifting.
Installation Accessories Determine whether freeze protection, mounting materials, or other accessories are required for the installation.
Final System Design SANCO₂ recommends determining heat pump/tank layout and piping as part of the commercial system design process.

Technical Documents

Controller documents apply when the optional ECO-CMB-BAC controller is included. Commercial warranty eligibility depends on the installed component models, application, installation, and policy conditions.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.