Lawler 310-75 Standard Point Of Use Mixing Valve 72049
Lawler’s 310® thermostatic mixing valve (Type T) meets your specification for a small (1/2″ NPT) under-the-counter master controller for individual or multiple fixtures at point-of-use. The Model 310® contains a highly sensitive thermostatic element that automatically responds to temperature and pressure variations in hot and cold water lines. The stainless steel piston and liner precisely proportion water flow to maintain a constant outlet temperature and to guard against unexpected hot or cold water spikes. For higher capacity needs, the Model 310® is available with a 3/4″ NPT outlet. Model 310® precisely controls outlet temperatures to within ±3o with flow rates of .5 to 7 GPM or .5 to 12 GPM at 45 psi (based on your choice of outlet piping size). The Model 310® can be installed with or without cabinet.
Specifications:
Series: 310 |
Model: 310-75 |
Configuration: Standard |
Engineering Number: 72049 |
Application: Point of use |
Certification/s: ASME A112, ASSE 1016, CSA B125 |
Connection Type: NPT |
Inlet Connection Size: 3/4" |
Outlet Connection Size: 3/4" |
Min Flow: 1/2 GPM |
Min Flow With Recirculation: N/A |
Rated Flow at 10 PSI: 5-1/2 GPM |
Rate Flow at 45 PSI: 12 GPM |
Temperature Range: 100°F – 150°F, 50°F – 100°F, 85°F – 135°F |
Finish: Polished Chrome 72049-61, Rough Brass 72049-00 |
Documents and guides:
Questions?
Speak with an expert