Free help & advice support@plumbestore.com

  • Free basic shipping over $35

    LTL freight charges may apply

  • Free help & advice

    Questions welcome!

  • Stock items ship same day

    For orders before 1pm CST

  • Open Mon-Fri

    9AM-5PM CST

Thermo2000  |  SKU: ALT208V3P7KW

AltSource 120 3 Phase 6.8 kW - 60 kw

Regular price $7,431.67
Shipping calculated at checkout.
Voltage
kW
DHW Coil

AltSource 120 3-Phase Commercial Electric Boiler & Storage Tank

Available with or without an optional copper coil heat exchanger.

The Thermo 2000 AltSource 120 combines an electric hydronic boiler with a 120-US-gallon storage tank. It stores heat from a primary renewable energy source and supplies auxiliary electric heat when needed. An optional immersed copper coil heat exchanger heats or preheats domestic water.

SCR power modulation adjusts output from 0 to 100% according to demand. Three-phase models are offered in 208V, 240V, 480V and 600V configurations; output depends on the selected model and supply voltage.

Key Features & Benefits

  • Thermal storage: High water volume stores energy for later heating demand.
  • Modulating electric backup: SCR control manages heat output and limits maximum electrical demand.
  • Electronic control: A Schneider Electric controller provides temperature and power settings, outdoor reset and operating information.
  • Building-system integration: BACnet IP/MS/TP communication and external 0–10V control support coordinated operation.
  • Optional domestic hot water: The copper coil configuration transfers heat to potable water.
  • Service access: Separate cabinet compartments provide access to heating elements and control components.

AltSource 120 Technical Specifications

Specification Details
Manufacturer Thermo 2000
Product type Commercial electric hydronic boiler and storage tank
Tank volume 120 US gallons
Electrical supply 3-phase, 60 Hz; 208V, 240V, 480V or 600V, model-dependent
208V output 6.8–54.1 kW, according to the model tables
240V / 480V / 600V output 9–60 kW, model-dependent
Power modulation 0–100% using a solid-state SCR relay
Controller Schneider Electric electronic controller
Temperature set point 50–200°F (10–93°C)
Product dimensions 36 in W × 36.5 in D × 78 in H
Weight without optional coil 530 lb — manufacturer-listed unit weight
Weight with optional coil 630 lb — manufacturer-listed unit weight
Tank construction Steel pressure vessel
Insulation Polyurethane foam
Tank / optional coil warranty 10-year limited warranty; tank coverage for closed-circuit heating applications
Parts and accessories warranty 2 years

Unit weights are not palletized shipping weights. Dimensions and weights are listed in the manufacturer flyer; warranty terms and control details follow the August 2026 specifications. See Technical Documents Below.

Configurations & Available Options

Specification Details
Without copper coil Hydronic heating and thermal storage; does not include the domestic-water coil.
With copper coil Adds an immersed heat exchanger for heating or preheating domestic water.

Options are configuration-dependent and are not all included as standard equipment. Confirm the selected configuration before ordering.

Component Reference

AltSource 120 cutaway showing numbered components and the optional copper coil heat exchanger
Optional copper coil configuration shown. 

Reference numbers correspond to the manufacturer’s illustrated component diagram in the brochure found below in Technical Documents.

3-Phase Model Specifications

Model identifiers and rated outputs are shown separately. The 208V models use 240V-rated elements operated at 208V.

All models are AltSource 120. Model labels below show the nominal kW identifier; the heading supplies voltage and phase. Rated output is listed separately. Electrical details display as labeled rows on phones.

208V — 3 Phase

Heating Output
Model BTU/h kW Amps
7KW 23065 6.8 19
10KW 34598 10.1 28
11KW 38442 11.3 31
14KW 46130 13.5 37
20KW 69195 20.3 56
23KW 76884 22.5 62
27KW 92260 27.0 75
30KW 103793 30.4 84
34KW 115326 33.8 94
41KW 138391 40.6 113
45KW 153767 45.1 125
54KW 184521 54.1 150
Electrical Components
Model Stages Elements (240V) Relay stages SCR stage
7KW 1 3 x 3 kW N.A. 1 x 6.8 kW
10KW 1 3 x 4.5 kW N.A. 1 x 10.1 kW
11KW 1 3 x 5 kW N.A. 1 x 11.3 kW
14KW 1 3 x 6 kW N.A. 1 x 13.5 kW
20KW 2 6 x 4.5 kW 1 x 10.1 kW 1 x 10.1 kW
23KW 2 6 x 5 kW 1 x 11.3 kW 1 x 11.3 kW
27KW 2 6 x 6 kW 1 x 13.5 kW 1 x 13.5 kW
30KW 3 9 x 4.5 kW 2 x 10.1 kW 1 x 10.1 kW
34KW 3 9 x 5 kW 2 x 11.3 kW 1 x 11.3 kW
41KW 3 9 x 6 kW 2 x 13.5 kW 1 x 13.5 kW
45KW 4 12 x 5 kW 3 x 11.3 kW 1 x 11.3 kW
54KW 4 12 x 6 kW 3 x 13.5 kW 1 x 13.5 kW

208V 3-phase supply: L1–L2–L3, three 75°C conductors and a ground, as specified by the manufacturer. Refer to the installation manual for wiring and protection requirements.

240V — 3 Phase

Heating Output
Model BTU/h kW Amps
9KW 30708 9 22
13KW 46062 13.5 32
15KW 51180 15 36
18KW 61416 18 43
27KW 92124 27 65
30KW 102360 30 72
36KW 122832 36 87
41KW 138186 40.5 97
45KW 153540 45 108
54KW 184248 54 130
60KW 204720 60 144
Electrical Components
Model Stages Elements (240V) Relay stages SCR stage
9KW 1 3 x 3 kW N.A. 1 x 9 kW
13KW 1 3 x 4.5 kW N.A. 1 x 13.5 kW
15KW 1 3 x 5 kW N.A. 1 x 15 kW
18KW 1 3 x 6 kW N.A. 1 x 18 kW
27KW 2 6 x 4.5 kW 1 x 13.5 kW 1 x 13.5 kW
30KW 2 6 x 5 kW 1 x 15 kW 1 x 15 kW
36KW 2 6 x 6 kW 1 x 18 kW 1 x 18 kW
41KW 3 9 x 4.5 kW 2 x 13.5 kW 1 x 13.5 kW
45KW 3 9 x 5 kW 2 x 15 kW 1 x 15 kW
54KW 3 9 x 6 kW 2 x 18 kW 1 x 18 kW
60KW 4 12 x 5 kW 3 x 15 kW 1 x 15 kW

240V 3-phase supply: L1–L2–L3, three 75°C conductors and a ground, as specified by the manufacturer. Refer to the installation manual for wiring and protection requirements in the Technical Documents found below.

480V — 3 Phase

Heating Output
Model BTU/h kW Amps
9KW 30708 9 10.8
15KW 51180 15 18.0
18KW 61416 18 21.7
30KW 102360 30 36.1
36KW 122832 36 43.3
45KW 153540 45 54.1
54KW 184248 54 65
60KW 204720 60 72.2
Electrical Components
Model Stages Elements (277V) Relay stages SCR stage
9KW 1 3 x 3 kW N.A. 1 x 9 kW
15KW 1 3 x 5 kW N.A. 1 x 15 kW
18KW 1 3 x 6 kW N.A. 1 x 18 kW
30KW 2 6 x 5 kW 1 x 15 kW 1 x 15 kW
36KW 2 6 x 6 kW 1 x 18 kW 1 x 18 kW
45KW 3 9 x 5 kW 2 x 15 kW 1 x 15 kW
54KW 3 9 x 6 kW 2 x 18 kW 1 x 18 kW
60KW 4 12 x 5 kW 3 x 15 kW 1 x 15 kW

480V 3-phase supply: L1–L2–L3, three 75°C conductors and a ground, as specified by the manufacturer. Refer to the installation manual for wiring and protection requirements found in the Technical Documents below.

600V — 3 Phase

Heating Output
Model BTU/h kW Amps
9KW 30708 9 8.7
15KW 51180 15 14.4
18KW 61416 18 17.3
30KW 102360 30 28.9
36KW 122832 36 34.6
45KW 153540 45 43.3
54KW 184248 54 52
60KW 204720 60 57.7
Electrical Components
Model Stages Elements (347V) Relay stages SCR stage
9KW 1 3 x 3 kW N.A. 1 x 9 kW
15KW 1 3 x 5 kW N.A. 1 x 15 kW
18KW 1 3 x 6 kW N.A. 1 x 18 kW
30KW 2 6 x 5 kW 1 x 15 kW 1 x 15 kW
36KW 2 6 x 6 kW 1 x 18 kW 1 x 18 kW
45KW 3 9 x 5 kW 2 x 15 kW 1 x 15 kW
54KW 3 9 x 6 kW 2 x 18 kW 1 x 18 kW
60KW 4 12 x 5 kW 3 x 15 kW 1 x 15 kW

600V 3-phase supply: L1–L2–L3, three 75°C conductors and a ground, as specified by the manufacturer. Refer to the installation manual for wiring and protection requirements found in the Technical Documents below.

Limited Warranty

Coverage Terms
Tank and optional heat exchanger 10 years from purchase for leaks caused by defective materials or workmanship, for the original commercial purchaser.
Other components 2 years against defects in materials or workmanship.
Excluded costs Removal, reinstallation, shipping and handling are the purchaser’s responsibility.
Conditions and claims Installation, maintenance and water-quality conditions apply. Submit claims through an authorized retailer with the required purchase and product records.

Technical Documents

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.