Senville AURA 36,000 BTU Tri-Zone Ceiling Cassette Mini Split Heat Pump – SENA-36HF/TIC
Senville AURA 36,000 BTU Tri-Zone Ceiling Cassette Mini Split Heat Pump – SENA-36HF/TIC - 12K + 12K + 12K / 16' + 16' + 16' is backordered and will ship as soon as it is back in stock.
Product availability changes quickly. Contact our customer service to confirm availability and lead time before purchasing. Email support@plumbestore.com or call 888-615-0755
Senville AURA 36,000 BTU Tri-Zone Ceiling Cassette Mini Split Heat Pump
The Senville AURA SENA-36HF/TIC is a high-efficiency, cold-climate mini split heat pump system designed to provide heating and cooling in three independently controlled zones from one outdoor condenser.
Featuring recessed ceiling cassette air handlers, the system delivers conditioned air while minimizing the amount of visible indoor equipment. It is well suited for residential and light commercial spaces where maintaining usable wall space and a clean appearance are important.
The AURA system combines inverter compressor technology, 23 SEER2 efficiency, R-454B refrigerant and heat pump operation down to -22°F (-30°C). Each indoor cassette can be controlled separately to accommodate different room temperatures and comfort preferences.
Key Features & Benefits
- Three independent zones: Control the temperature in three different rooms or areas using one outdoor system.
- Discreet ceiling cassette design: Recessed indoor units help preserve wall space and provide an integrated look.
- Cold-climate heat pump: Designed to operate in heating mode at outdoor temperatures down to -22°F.
- Energy-efficient operation: Up to 23 SEER2 with variable-speed inverter technology.
- R-454B refrigerant: Uses the manufacturer's current lower-GWP refrigerant platform.
- Year-round comfort: Provides air conditioning, heat pump heating and dehumidification.
- Comfort controls: Includes Follow Me functionality, timer operation and diagnostic features.
- Manufacturer warranty: 10 years on the compressor and 5 years on covered parts, subject to terms.
Available System Configurations
This family is offered in multiple ceiling cassette combinations, allowing the indoor unit sizes to be selected according to the heating and cooling requirements of each zone.
| System SKU | Indoor Configuration |
|---|---|
| SENA-36HF-TIC121212 | 12,000 + 12,000 + 12,000 BTU |
| SENA-36HF-TIC121218 | 12,000 + 12,000 + 18,000 BTU |
System combinations and installation-kit availability vary. Confirm current options with customer service before purchasing. The outdoor system's nominal rated capacity is 36,000 BTU regardless of the sum of connected indoor-unit nameplate capacities.
Installation Kit Options
Standard configurations include three 16-foot installation kits. Longer insulated refrigerant line-set combinations may be available depending on the selected variant.
| Line Set Selection | Configuration |
|---|---|
| Standard | 16 ft / 16 ft / 16 ft |
| 25 ft Upgrade - One | 16 ft / 16 ft / 25 ft |
| 25 ft Upgrade - Two | 16 ft / 25 ft / 25 ft |
| 50 ft Upgrade - One | 16 ft / 16 ft / 50 ft |
| 50 ft Upgrade - Two | 16 ft / 50 ft / 50 ft |
Extended line-set options are subject to manufacturer availability, approved piping limits and any necessary refrigerant charge adjustments. Professional installation is required.
Technical Specifications
| Specification | Value |
|---|---|
| Outdoor Unit | SENA-36HF-MOA |
| System Capacity | 36,000 BTU |
| Indoor Zones | 3 |
| Cooling Capacity Range | 9,000-43,000 BTU |
| Heating Capacity Range | 10,000-44,000 BTU |
| SEER2 | 23 |
| EER2 | 13 |
| HSPF2 Region IV | 10.7 |
| HSPF2 Region V | 8.5 |
| COP | 4.0 |
| Electrical Supply | 208/230V, 1Ph, 60Hz |
| Minimum Circuit Ampacity | 37A |
| Maximum Fuse | 40A |
| Refrigerant | R-454B |
| Factory Refrigerant Charge | 134.04 oz |
| Combined Pre-Charge Length | 100 ft |
| Outdoor Dimensions | 38.58 x 16.34 x 38.39 in |
| Outdoor Weight | 211.86 lb |
| Lowest Heating Temperature | -22°F (-30°C) |
| Manufacturer Warranty | 10-Year Compressor / 5-Year Parts |
Ceiling Cassette Comfort
Ceiling cassette mini splits are designed to distribute conditioned air from an overhead location. Unlike wall-mounted air handlers, cassette systems can be integrated into an appropriate ceiling cavity to reduce visual impact.
The tri-zone arrangement can provide individualized comfort for separate offices, bedrooms, living areas and other spaces. A qualified HVAC contractor should calculate the heating and cooling load of each zone before selecting indoor unit capacities.
Senville AURA Heating & Cooling Video
Learn about the Senville AURA Series, including inverter heating and cooling, energy-efficient operation and cold-climate heat pump technology.
Professional Installation Requirements
Professional HVAC installation is required. The installer must verify indoor cassette sizing, ceiling clearances, condensate drainage, electrical supply, refrigerant piping, evacuation and system commissioning.
The system is factory charged with R-454B refrigerant for up to 100 feet of combined line-set length. All piping limits and additional charge requirements must be verified in the applicable installation manual before installation.
Technical Documentation
Ceiling Cassette Indoor Units
- Ceiling Cassette Owner's Manual
- Ceiling Cassette Installation Manual
- Ceiling Cassette Service Manual
Multi-Zone Outdoor Unit
Manufacturer Warranty
Senville provides limited warranty coverage for qualifying systems, including 10-year compressor coverage and 5-year parts coverage. All warranty coverage is subject to the manufacturer's requirements, including qualifying professional installation and applicable warranty conditions.
Senville AURA 36,000 BTU Tri-Zone Ceiling Cassette Mini Split Heat Pump – SENA-36HF/TIC - 12K + 12K + 12K / 16' + 16' + 16' is backordered and will ship as soon as it is back in stock.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.