Senville SENDC Central Air Conditioner Heat Pump Systems
Senville SENDC Central Air Conditioner Heat Pump Systems - 36000 / None / 16Ft is backordered and will ship as soon as it is back in stock.
Product availability changes quickly. Contact our customer service to confirm availability and lead time before purchasing. Email support@plumbestore.com or call 888-615-0755
The Senville SENDC Series combines central ducted air conditioning and heat-pump heating with variable-speed inverter technology. This family includes 36,000, 48,000 and 60,000 BTU-class systems for residential and light-commercial ducted applications.
The inverter-driven compressor adjusts system output as heating and cooling demands change. A matching indoor air handler distributes conditioned air through central ductwork, providing whole-building comfort from a coordinated indoor and outdoor system.
These systems use R-454B refrigerant and operate on 208/230V single-phase power. Manufacturer-listed efficiency ratings vary by capacity. Warranty coverage includes 10 years on the compressor and 5 years on parts, subject to Senville’s terms.
Professional sizing and installation are required. A qualified HVAC professional must confirm the building load, ductwork, equipment compatibility, electrical requirements and auxiliary-heater selection.
Key Features
- Central heating and cooling: Matched indoor and outdoor equipment serves a central duct system.
- Variable-speed inverter operation: System output adjusts to changing comfort demands.
- Three capacity classes: 36,000, 48,000 and 60,000 BTU options.
- R-454B refrigerant: Current-generation central heat-pump platform.
- Supplemental heat configurations: Listed 36,000 BTU options include 10-kW and 15-kW auxiliary electric heaters.
- 16-ft installation configuration: The SKUs listed below use the 16-ft installation-kit selection.
- Manufacturer warranty: 10-year compressor and 5-year parts coverage, subject to installation requirements and warranty terms.
Model Comparison
| Model Detail | 36,000 BTU | 48,000 BTU | 60,000 BTU Class |
|---|---|---|---|
| Base System SKU | SENDC-36HF-16 |
SENDC-48HF-16 |
SENDC-60HF-16 |
| System Type | Central ducted heat pump | Central ducted heat pump | Central ducted heat pump |
| Installation Kit | 16 ft. | 16 ft. | 16 ft. |
| Auxiliary Heater in Base SKU | None selected | None selected | None selected |
| Power Supply | 208/230V, 1-phase, 60Hz | 208/230V, 1-phase, 60Hz | 208/230V, 1-phase, 60Hz |
| Refrigerant | R-454B | R-454B | R-454B |
Performance Specifications
| Specification | 36,000 BTU | 48,000 BTU | 60,000 BTU Class |
|---|---|---|---|
| SEER2 | 17.4 | 16.5 | 16 |
| EER2 | 11.7 | 10.5 | 10 |
| Cooling Range | 13,000–47,400 BTU/h | 15,600–51,000 BTU/h | 11,400–56,300 BTU/h |
| Heating Range | 11,000–57,200 BTU/h | 15,500–57,300 BTU/h | 8,100–64,500 BTU/h |
| HSPF2-4 | 10.3 | 9.5 | 9 |
| HSPF2-5 | 7.8 | 8 | 8 |
| COP | 3.36 | 3.4 | 3.1 |
| Voltage Range | 187–253V | 187–253V | 187–253V |
Nominal model size may differ from rated capacity. The 60,000 BTU-class model is listed with 54,000 BTU/h rated cooling and 56,000 BTU/h rated heating. Performance depends on operating conditions and the installed system.
Product Dimensions & Weight
| Specification | 36,000 BTU | 48,000 BTU | 60,000 BTU Class |
|---|---|---|---|
| Indoor Dimensions | 21.02″ × 21.02″ × 49.02″ | 21.02″ × 24.49″ × 52.99″ | 21.02″ × 24.49″ × 52.99″ |
| Indoor Weight | 129.19 lb | Verify with Manufacturer | 162.92 lb |
| Outdoor Dimensions | 38.58″ × 16.34″ × 38.39″ | Verify with Manufacturer | 37.48″ × 16.34″ × 52.48″ |
| Outdoor Weight | 227 lb | Verify with Manufacturer | 242.95 lb |
Dimensions and weights describe individual equipment components, not combined system shipping weight or palletized freight measurements. Confirm dimensions and installation clearances using the exact equipment model documentation.
36,000 BTU Auxiliary-Heat Configurations
| System SKU | Configuration |
|---|---|
SENDC-36HF-16 |
No auxiliary heater selected; 16-ft installation kit. |
SENDC-36HF-10K-16 |
10-kW auxiliary electric heater; 16-ft installation kit. |
SENDC-36HF-15K-16 |
15-kW auxiliary electric heater; 16-ft installation kit. |
The auxiliary-heat configurations share the SENDC-36HF heat-pump platform. Electric heater selection changes supplemental heating and electrical requirements; it does not change the heat pump’s published efficiency rating. Have your HVAC professional verify heater compatibility, wiring and circuit requirements.
Included System Components
- Matching indoor central air handler.
- Outdoor inverter heat-pump condenser.
- 16-ft installation-kit configuration.
- Auxiliary electric heater when selecting
SENDC-36HF-10K-16orSENDC-36HF-15K-16.
Confirm the supplied thermostat/control, communication wiring and other installation components for the selected SKU before ordering. Ductwork, electrical installation and professional labor must be planned separately.
Product Highlights
- Central ducted heating and cooling from a matched system.
- Variable-speed operation adapts to changing demand.
- Three nominal capacity classes support different building loads.
- 36,000 BTU supplemental-heat configurations.
- Professional system design supports proper equipment selection.
Technical Document References
- Senville SENDC Central System Owner’s Manual.
- Senville R-454B AHU Central Installation Manual.
- Senville SENDC Central System Service Manual.
- Senville warranty
Use documentation that matches the equipment rating labels, refrigerant generation and selected auxiliary-heater configuration.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.